| Unit type | Product name | Specifications | No. of words allo- cated | Current consump- tion (A) | Model | Stand- ards | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Output type | I/O points | Maximum switching capacity | Commons | External con- nection | 5 V | 24 V | |||||
| CJ1 Basic I/O Units | Relay Contact Output Units | --- | 8 outputs | 250 VAC/ 24 VDC, 2 A | Inde- pendent contacts | Removable terminal block | 1 words | 0.09 | 0.048 max. | CJ1W-OC201 | UC1, N, L, CE |
| --- | 16 outputs | 250 VAC/ 24 VDC, 2 A | 16 points, 1 common | Removable terminal block | 1 words | 0.11 | 0.096 max. | CJ1W-OC211 | |||
| Triac Output Unit | --- | 8 outputs | 250 VAC, 0.6 A | 8 points, 1 common | Removable terminal block | 1 words | 0.22 | --- | CJ1W-OA201 | ||
| Tran- sistor Output Units | Sinking | 8 outputs | 12 to 24 VDC, 2 A | 4 points, 1 common | Removable terminal block | 1 words | 0.09 | --- | CJ1W-OD201 | ||
| Sinking | 8 outputs | 12 to 24 VDC, 0.5 A | 8 points, 1 common | Removable terminal block | 1 words | 0.10 | --- | CJ1W-OD203 | |||
| Sinking | 16 outputs | 12 to 24 VDC, 0.5 A | 16 points, 1 common | Removable terminal block | 1 words | 0.10 | --- | CJ1W-OD211 | |||
| Sinking | 16 outputs (High speed) | 24 VDC, 0.5 A | 16 points, 1 common | Removable terminal block | 1 words | 0.15 | --- | CJ1W-OD213 | N, L, CE | ||
| Sinking | 32 outputs | 12 to 24 VDC, 0.5 A | 16 points, 1 common | Fujitsu connector | 2 words | 0.14 | --- | CJ1W-OD231 | UC1, N, L, CE | ||
| Sinking | 32 outputs | 12 to 24 VDC, 0.5 A | 16 points, 1 common | MIL connector | 2 words | 0.14 | --- | CJ1W-OD233 | |||
| Sinking | 32 outputs (High speed) | 24 VDC, 0.5 A | 16 points, 1 common | MIL connector | 2 words | 0.22 | --- | CJ1W-OD234 | N, L, CE | ||
| Sinking | 64 outputs | 12 to 24 VDC, 0.3 A | 16 points, 1 common | Fujitsu connector | 4 words | 0.17 | --- | CJ1W-OD261 | UC1, N, L, CE | ||
| Sinking | 64 outputs | 12 to 24 VDC, 0.3 A | 16 points, 1 common | MIL connector | 4 words | 0.17 | --- | CJ1W-OD263 | |||
| Sourcing | 8 outputs | 24 VDC, 2 A Short- circuit protection | 4 points, 1 common | Removable terminal block | 1 words | 0.11 | --- | CJ1W-OD202 | |||
| Sourcing | 8 outputs | 24 VDC, 0.5 A Short- circuit protection | 8 points, 1 common | Removable terminal block | 1 words | 0.10 | --- | CJ1W-OD204 | |||
| Sourcing | 16 outputs | 24 VDC, 0.5 A Short- circuit protection | 16 points, 1 common | Removable terminal block | 1 words | 0.10 | --- | CJ1W-OD212 | |||
| Sourcing | 32 outputs | 24 VDC, 0.5 A Short- circuit protection | 16 points, 1 common | MIL connector | 2 words | 0.15 | --- | CJ1W-OD232 | |||
| Sourcing | 64 outputs | 12 to 24 VDC, 0.3 A | 16 points, 1 common | MIL connector | 4 words | 0.17 | --- | CJ1W-OD262 | |||
Connectors are not included for models with connectors. Either use one of the applicable connector listed below or use an applicable Connector-Terminal Block Conversion Unit or I/O Relay Terminal. For details on wiring methods, refer to Data Sheet.
| Name | Con- nection | Remarks | Applicable Units | Model | Stand- ards | |
|---|---|---|---|---|---|---|
| 40-pin Con- nectors | Soldered | FCN-361J040-AU | Connector | Fujitsu Connectors: CJ1W-ID231(32 inputs): 1 per Unit CJ1W-ID261 (64 inputs): 2 per Unit CJ1W-OD231 (32 outputs):1 per Unit CJ1W-OD261 (64 outputs): 2 per Unit CJ1W-MD261 (32 inputs, 32 outputs): 2 per Unit | C500-CE404 | --- |
| FCN-360C040-J2 | Connector Cover | |||||
| Crimped | FCN-363J040 | Housing | C500-CE405 | |||
| FCN-363J-AU | Contactor | |||||
| FCN-360C040-J2 | Connector Cover | |||||
| Pressure welded | FCN-367J040-AU/F | C500-CE403 | ||||
| 24-pin Con- nectors | Soldered | FCN-361J024-AU | Connector | Fujitsu Connectors: CJ1W-MD231 (16 inputs, 16 outputs): 2 per Unit | C500-CE241 | |
| FCN-360C024-J2 | Connector Cover | |||||
| Crimped | FCN-363J024 | Socket | C500-CE242 | |||
| FCN-363J-AU | Contactor | |||||
| FCN-360C024-J2 | Connector Cover | |||||
| Pressure welded | FCN-367J024-AU/F | C500-CE243 | ||||
| Name | Con- nection | Remarks | Applicable Units | Model | Stand- ards |
|---|---|---|---|---|---|
| 40-pin Con- nectors | Pressure welded | FRC5-AO40-3TOS | MIL Connectors: CJ1W-ID232/233 (32 inputs): 1 per Unit CJ1W-OD232/233/234 (32 outputs):1 per Unit CJ1W-ID262 (64 inputs): 2 per Unit CJ1W-OD262/263 (64 outputs): 2 per Unit CJ1W-MD263/563 (32 inputs, 32 outputs): 2 per Unit | XG4M-4030-T | --- |
| Crimped | - | XG5N-401 * | |||
| 20-pin Con- nectors | Pressure welded | FRC5-AO20-3TOS | MIL Connectors: CJ1W-MD232/233 (16 inputs, 16 outputs): 2 per Unit | XG4M-2030-T | --- |
| Crimped | - | XG5N-201 * |
* Crimp Contacts are also required. Refer to Data Sheet for details.
Size and Mounting are Refer to Data Sheet.
| Type/ Series | Num- ber of poles | Wiring method | Ter- minal type | Common terminals | I/O Units | Model * | Stand- ards |
|---|---|---|---|---|---|---|---|
| Bleeder resistance | |||||||
| Indicators | |||||||
| PLCs/ XW2R | 34 | Phillips screw | M3 | No | CJ1W-OD231 CJ1W-OD261 | XW2R-J34GD-C3 | --- |
| CJ1W-OD232 CJ1W-OD233 CJ1W-OD234 CJ1W-OD262 CJ1W-OD263 | XW2R-J34GD-C4 | ||||||
| Slotted screw (rise up) | M3 (Euro- pean type) | CJ1W-OD231 CJ1W-OD261 | XW2R-E34GD-C3 | ||||
| CJ1W-OD232 CJ1W-OD233 CJ1W-OD234 CJ1W-OD262 CJ1W-OD263 | XW2R-E34GD-C4 | ||||||
| Push-in spring | Clamp | CJ1W-OD231 CJ1W-OD261 | XW2R-P34GD-C3 | ||||
| CJ1W-OD232 CJ1W-OD233 CJ1W-OD234 CJ1W-OD262 CJ1W-OD263 | XW2R-P34GD-C4 |
| Appearance | Connectors | Cable lenght [m] | Model |
|---|---|---|---|
XW2Z-[][][]B![]() | One 40-pin Fujitsu Connector to One 40-pin MIL Connector | 0.5 | XW2Z-050B |
| 1 | XW2Z-100B | ||
| 1.5 | XW2Z-150B | ||
| 2 | XW2Z-200B | ||
| 3 | XW2Z-300B | ||
| 5 | XW2Z-500B | ||
XW2Z-[][][]K![]() | One 40-pin MIL Connector to One 40-pin MIL Connector | 0.5 | XW2Z-C50K |
| 1 | XW2Z-100K | ||
| 1.5 | XW2Z-150K | ||
| 2 | XW2Z-200K | ||
| 3 | XW2Z-300K | ||
| 5 | XW2Z-500K |
Size (horizontal mounting) and Mounting are Refer to Data Sheet.
| Type/ Series | Specifications | Model | Stand- ards | |||||
|---|---|---|---|---|---|---|---|---|
| Classification | Po- lar- ity | Number of points | Rated ON cur- rent at contacts | Rated voltage | ||||
| Push-In Plus terminal block/ G70V | In- puts | DC inputs | NPN | 16 (SPST- NO × 16) | 50 mA | 24 VDC | G70V-SID16P *4 | UC, CE (TÜV certi- fied) |
| PNP | G70V-SID16P-1 *4 | |||||||
| NPN | G70V-SID16P-C16 *5 | |||||||
| PNP | G70V-SID16P-1-C16 *5 | |||||||
| Out- puts | Relay outputs | NPN | 16 (SPDT × 16) | 6 A/ point, 10 A/ common | G70V-SOC16P *4 | |||
| PNP | G70V-SOC16P-1 *4 | |||||||
| NPN | G70V-SOC16P-C4 *6 | |||||||
| PNP | G70V-SOC16P-1-C4 *6 | |||||||
| Standard/ G7TC | In- puts | AC inputs | NPN | 16 (SPST- NO × 16) | 1A | 100/(110) VAC | G7TC-IA16 AC100/110 | U, C |
| 200/(220) VAC | G7TC-IA16 AC200/220 | |||||||
| DC inputs | 12 VDC | G7TC-ID16 DC12 | ||||||
| 24 VDC | G7TC-ID16 DC24 | |||||||
| 100/110 VDC | G7TC-ID16 DC100/110 | |||||||
| Out- puts | Relay outputs | NPN | 8 (SPST- NO × 8) | 5A | 12 VDC | G7TC-OC08 DC12 | ||
| 24 VDC | G7TC-OC08 DC24 | |||||||
| 16 (SPST- NO × 16) | 12 VDC | G7TC-OC16 DC12 | ||||||
| 24 VDC | G7TC-OC16 DC24 | |||||||
| PNP | 16 (SPST- NO × 16) | 12 VDC | G7TC-OC16-1 DC12 | |||||
| 24 VDC | G7TC-OC16-1 DC24 | |||||||
| High- capacity socket/ G70A *1 (Socket only) | In- puts | Relay inputs | NPN/ PNP | 16 (SPDT × 16 possible with G2R Relays) | 100 mA | 110 VDC max., 240 VAC max. *2 | G70A-ZOC16-5 | U, C, CE (VDE certi- fied) |
| Out- puts | Relay outputs | NPN | 10 A (Terminal block allowable | 24 VDC | G70A-ZOC16-3 | |||
| PNP | G70A-ZOC16-4 | |||||||
| Space- saving/ Vertical type G70D-V | Out- puts | Relay outputs | NPN | 16 (SPST- NO × 16) | 5 A or 3 A *3 | 24 VDC | G70D-VSOC16 | U, C, CE (VDE certi- fied) |
| MOSFET relay outputs | 0.3 A | G70D-VFOM16 | ||||||
| Space- saving/ Flat type G70D | Relay outputs | NPN | 8 (SPST- NO × 8) | 5 A | G70D-SOC08 | - | ||
| 16 (SPST- NO × 16) | 3 A | G70D-SOC16 | ||||||
| PNP | 16 (SPST- NO × 16) | 3 A | G70D-SOC16-1 | |||||
| MOSFET relay outputs | NPN | 16 (SPST- NO × 16) | 0.3 A | G70D-FOM16 | ||||
| PNP | G70D-FOM16-1 *7 | |||||||
| High- capacity, space- saving/ G70R | Out- puts | Relay outputs | NPN | 8 (SPST- NO × 8) | 10 A | 24 VDC | G70R-SOC08 *7 | - |
| Type | Name | I/O Classifi- cation | Appearance | Cable length L (mm) | Models |
|---|---|---|---|---|---|
| Fujitsu connectors (24 pins) | Cables with Connectors (1:1) XW2Z-R[]C | 16 I/O points | ![]() | 1,000 | XW2Z-R100C |
| 1,500 | XW2Z-R150C | ||||
| 2,000 | XW2Z-R200C | ||||
| 3,000 | XW2Z-R300C | ||||
| 5,000 | XW2Z-R500C | ||||
| Fujitsu connectors (40 pins) | Cables with Connectors (1:2) XW2Z-RI[]C-[] XW2Z-RO[]C-[] | 32 input points | ![]() | (A) 1,000 (B) 750 | XW2Z-RI100C-75 |
| (A) 1,500 (B) 1,250 | XW2Z-RI150C-125 | ||||
| (A) 2,000 (B) 1,750 | XW2Z-RI200C-175 | ||||
| (A) 3,000 (B) 2,750 | XW2Z-RI300C-275 | ||||
| (A) 5,000 (B) 4,750 | XW2Z-RI500C-475 | ||||
| 32 output points | (A) 1,000 (B) 750 | XW2Z-RO100C-75 | |||
| (A) 1,500 (B) 1,250 | XW2Z-RO150C-125 | ||||
| (A) 2,000 (B) 1,750 | XW2Z-RO200C-175 | ||||
| (A) 3,000 (B) 2,750 | XW2Z-RO300C-275 | ||||
| (A) 5,000 (B) 4,750 | XW2Z-RO500C-475 | ||||
| MIL connectors (20 pins) | Cables with Connectors (1:1) XW2Z-RI[]C XW2Z-RO[]C | 16 I/O points | ![]() | 250 | XW2Z-RI25C |
| 500 | XW2Z-RI50C | ||||
| 250 | XW2Z-RO25C | ||||
| 500 | XW2Z-RO50C | ||||
| MIL connectors (40 pins) | Cables with Connectors (1:2) XW2Z-RO[]-[]-D1, XW2Z-RI[]-[]-D1 | 32 I/O points | ![]() | (A) 500 (B) 250 | XW2Z-RO50-25-D1 |
| (A) 750 (B) 500 | XW2Z-RO75-50-D1 | ||||
| (A) 1,000 (B) 750 | XW2Z-RO100-75-D1 | ||||
| (A) 1,500 (B) 1,250 | XW2Z-RO150-125-D1 | ||||
| (A) 2,000 (B) 1,750 | XW2Z-RO200-175-D1 | ||||
| (A) 3,000 (B) 2,750 | XW2Z-RO300-275-D1 | ||||
| (A) 5,000 (B) 4,750 | XW2Z-RO500-475-D1 | ||||
| (A) 500 (B) 250 | XW2Z-RI50-25-D1 | ||||
| (A) 750 (B) 500 | XW2Z-RI75-50-D1 | ||||
| (A) 1,000 (B) 750 | XW2Z-RI100-75-D1 | ||||
| (A) 1,500 (B) 1,250 | XW2Z-RI150-125-D1 | ||||
| (A) 2,000 (B) 1,750 | XW2Z-RI200-175-D1 | ||||
| (A) 3,000 (B) 2,750 | XW2Z-RI300-275-D1 | ||||
| (A) 5,000 (B) 4,750 | XW2Z-RI500-475-D1 |